BH GSO ISO 21105-1:2023

Bahraini Standard   Current Edition
· Approved on 05 April 2023 ·

Performance of buildings — Building enclosure thermal performance verification and commissioning — Part 1: General requirements

Thermal insulation of buildings
Including energy efficiency of buildings

BH GSO ISO 21105-1:2023 Files

English 0 Pages
Current Edition Reference Language

BH GSO ISO 21105-1:2023 Scope

This document describes a building enclosure commissioning process to achieve a well performing, durable and maintainable building enclosure. This document includes procedures, methods and documentation requirements describing the application of the commissioning process to a building enclosure at each phase of a project. These project phases span from predesign through owner occupancy and operation. This process is referred to throughout this document as building enclosure commissioning (BECx).

This document applies to new building construction and building re-commissioning. This document is for use by an owner, commissioning provider, building developer, owner's representative, construction manager, architect, contractor, and/or consultant, etc. Its purpose is to determine and complete the required tasks and activities to deliver a building enclosure which meets the performance requirements of the owner. Requirements for the project are established by the owner and/or commissioning provider (CxP).

This document identifies steps necessary to perform a building enclosure risk analysis. The analysis will result in tasks that define the level of BECx, commensurate with the owner's tolerance for risk associated with building enclosure performance.

The BECx process covered by this document is applicable to an individual assembly, a combination of assemblies or a whole enclosure assembly. For example, an individual assembly can be the fenestration, the air barrier or the thermal insulation. A combination of assemblies would include the fenestration, the air barrier and the complete heat transfer system, (e.g. both the insulation and roof assembly). A whole building enclosure assembly would include all heat, air and moisture control layers of the building enclosure, on all six sides of the building.

This document describes requirements for any third-party consultants and/or building enclosure commissioning providers (BECxP) to document their technical qualifications, independence and knowledge of the BECx process, including their education, training, and experience.

Best Sellers From Construction and Building Sector

GSO 1431:2002
 
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 1427:2008
 
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 2084:2010
 
Gulf Standard
Design and application of speed control humps
GSO 1421:2002
 
Gulf Technical Regulation
Hollow blocks made from clay for walls

Recently Published from Construction and Building Sector

GSO ASTM E2129:2024
ASTM E2129:18 
Gulf Standard
Standard Practice for Data Collection for Sustainability Assessment of Building Products
GSO EN 196-3:2024
EN 196-3:2016 
Gulf Standard
Methods of testing cement - Part 3: Determination of setting times and soundness
GSO ASTM C114:2024
ASTM C114:23 
Gulf Standard
Standard Test Methods for Chemical Analysis of Hydraulic Cement
GSO EN 196-2:2024
EN 196-2:2013 
Gulf Standard
Method of testing cement - Part 2: Chemical analysis of cement